Gas and particulate
Gas flow, temperature, dust loading and particle characteristics establish the starting point for assessment.
Evapotech supports industrial environmental management through consultancy, testing, operations and maintenance, and products for air pollution control, water treatment, wastewater treatment, and environmental monitoring.






EVAPO TECHEvapo Tech supplies Venturi wet scrubber systems for particulate control in suitable process gas streams. The design discussion considers gas conditions, liquid requirements, pressure drop and the handling of the resulting liquid stream.
The gas path, liquid circuit and solids handling must work as one system.
Conceptual process summary
Gas accelerates through a narrowed Venturi throat and contacts scrubbing liquid. Contact between particles and droplets transfers particulate into the liquid stream, followed by droplet separation. The complete system must account for liquid circulation and collected solids.
Applications within the NPC empanelment include flue-gas emission control for boilers, furnaces and thermic fluid heaters. Suitability and performance requirements are assessed for each installation.
Gas flow, temperature, dust loading and particle characteristics establish the starting point for assessment.
Water quality, liquid chemistry and material compatibility need to be considered alongside circulation, make-up and blowdown requirements.
Discuss the Venturi arrangement, droplet separator, fan duty, recirculation equipment, solids handling and maintenance access.
Certificate NPC/ECAG/APCDES/EC/2026-27/012
Issued 27 May 2026 · Valid up to 27 May 2028, subject to the certificate conditions.
The certificate identifies the named APCD technology for boiler, furnace and thermic-fluid-heater flue-gas emission control under the NPC-APCDES scheme. It is limited to the empaneled equipment and is not blanket approval of other models or configurations.
Read both pages for eligibility, OEM responsibilities, surveillance and the conditions affecting validity.
Relevant checks include pressure drop, liquid flow, nozzle condition, droplet separation and the condition of circulating liquid. Water consumption, wastewater handling and maintenance belong in the operating plan.
Explore operations & maintenance supportSelection depends on the pollutants, gas conditions and operating requirements. A Venturi scrubber is primarily a particulate-control technology; gas absorption requirements need a separate assessment of pollutant chemistry and system configuration.
Share your site location, process and fuel or material handled, actual gas flow, temperature, pollutant data, available space and utilities, and the required emission objective. Include recent stack-test reports and existing-system drawings where available.
No. The certificate has a defined scope and conditions. The equipment specification, installation, commissioning, operation and performance verification must address the particular site and applicable requirements.
Email your process details, gas flow, operating conditions and emission objective. Our team will discuss the design basis, equipment scope and support requirements.
Dust Extraction System, Bag House Filter, ID fan and FD fan, Wet Water & Chemical Scrubber, Dry Chemical Scrubbers, Multi Cyclone Separator, Trema Cyclone, Multi Cyclone Systems
Sewage Treatment Plant, Effluent Treatment Plant, Skid Mounted ETP cum STP for Hospitals, Pan Evaporators, Electrocoagulation and Electro ionisation
Ambient Air Quality Monitor, Continuous Emission Monitoring Systems (CEMS), Effluent Quality Monitoring Systems, VOC Monitors, Sulphur dioxide Monitor and alarm systems (SO2 Monitors), Piezometers, Bag Fault Detection System, Telemetry based Ultrasonic flow meters