WELCOME TO EVAPOTECH

Environmental Services and Pollution Control Systems

Our Capabilities

Evapotech supports industrial environmental management through consultancy, testing, operations and maintenance, and products for air pollution control, water treatment, wastewater treatment, and environmental monitoring.

Environmental Services · Products & Systems

Our Capabilities

Environmental Consultancy

Technical guidance for environmental requirements, approvals, and documentation, tailored to your facility and project.

Environmental Testing

Environmental testing for water, wastewater, air, emissions, and soil. Contact our team to confirm the parameters and scope available for your requirement.

Operations & Maintenance

Operational support, preventive maintenance, and troubleshooting for pollution-control, treatment, and environmental monitoring systems.

Air Pollution Control

Equipment and systems for industrial air pollution control, including bag house filters. Discuss your process and emissions-control requirements with our team.

Water & Wastewater Treatment

Water treatment, industrial wastewater treatment, and sewage treatment systems matched to your facility’s needs.

Environmental Monitoring

Continuous online emission and effluent monitoring systems for industrial environmental monitoring requirements.
About Evapotech

Environmental expertise. Practical solutions.

Products / Air pollution control

Venturi Wet Scrubbers

Evapo Tech supplies Venturi wet scrubber systems for particulate control in suitable process gas streams. The design discussion considers gas conditions, liquid requirements, pressure drop and the handling of the resulting liquid stream.

The treatment sequence

Gas contact.
Particle capture.
Droplet separation.

The gas path, liquid circuit and solids handling must work as one system.

Conceptual process summary

Technology overview

Bring gas and liquid
into effective
contact.

How it works

Gas accelerates through a narrowed Venturi throat and contacts scrubbing liquid. Contact between particles and droplets transfers particulate into the liquid stream, followed by droplet separation. The complete system must account for liquid circulation and collected solids.

Technology reference: US EPA

Specify around your process

Define the duty.
Then define the system.

Applications within the NPC empanelment include flue-gas emission control for boilers, furnaces and thermic fluid heaters. Suitability and performance requirements are assessed for each installation.

Gas and particulate

Gas flow, temperature, dust loading and particle characteristics establish the starting point for assessment.

Liquid and materials

Water quality, liquid chemistry and material compatibility need to be considered alongside circulation, make-up and blowdown requirements.

System configuration

Discuss the Venturi arrangement, droplet separator, fan duty, recirculation equipment, solids handling and maintenance access.

What the empanelment covers

The certificate identifies the named APCD technology for boiler, furnace and thermic-fluid-heater flue-gas emission control under the NPC-APCDES scheme. It is limited to the empaneled equipment and is not blanket approval of other models or configurations.

Read both pages for eligibility, OEM responsibilities, surveillance and the conditions affecting validity.

Operation & maintenance

Plan for the
working life.

Relevant checks include pressure drop, liquid flow, nozzle condition, droplet separation and the condition of circulating liquid. Water consumption, wastewater handling and maintenance belong in the operating plan.

Explore operations & maintenance support
Common questions

Before you specify.

Is a Venturi scrubber the right choice for every emission stream?

Selection depends on the pollutants, gas conditions and operating requirements. A Venturi scrubber is primarily a particulate-control technology; gas absorption requirements need a separate assessment of pollutant chemistry and system configuration.

What should I send for an initial proposal?

Share your site location, process and fuel or material handled, actual gas flow, temperature, pollutant data, available space and utilities, and the required emission objective. Include recent stack-test reports and existing-system drawings where available.

Does empanelment guarantee compliance at every site?

No. The certificate has a defined scope and conditions. The equipment specification, installation, commissioning, operation and performance verification must address the particular site and applicable requirements.

Let’s talk about your site

Let’s define the right
system for your process.

Email your process details, gas flow, operating conditions and emission objective. Our team will discuss the design basis, equipment scope and support requirements.

Air Pollution Control System

Dust Extraction System, Bag House Filter, ID fan and FD fan, Wet Water & Chemical Scrubber, Dry Chemical Scrubbers, Multi Cyclone Separator, Trema Cyclone, Multi Cyclone Systems

Waste Water Treatment Plant

Sewage Treatment Plant, Effluent Treatment Plant, Skid Mounted ETP cum STP for Hospitals, Pan Evaporators, Electrocoagulation and Electro ionisation

Continuous Online Emission and Effluent Monitoring Systems

Ambient Air Quality Monitor, Continuous Emission Monitoring Systems (CEMS), Effluent Quality Monitoring Systems, VOC Monitors, Sulphur dioxide Monitor and alarm systems (SO2 Monitors), Piezometers, Bag Fault Detection System, Telemetry based Ultrasonic flow meters